25 KVA

25kva 5
Agrison Generator 25 KVA  (1)Agrison Generator 25 KVA  (1)Agrison Generator 25 KVA  (2)Agrison Generator 25 KVA  (3)Agrison Generator 25 KVA  (4)Agrison Generator 25 KVA  (5)Agrison Generator 25 KVA  (6)

25 KVA

$6,990.00

Enquire

Agrison Power Calculator Generators

SKU: Gen-25KVA Category: Tags: , , ,
Share:

Product Description

Agrison Diesel Generators have become a necessity for those who require mobile power, back up power or simply just power. The consequences of a sudden loss of power, or no power at all, is not only inconvenient but can also be costly. Agrison offers a wide range of diesel generators of different sizes and kW to suit your needs. Our Diesel Generators are used in a variety of applications and have become a popular choice in the Australian and International market place. Do not be left in the dark, get yourself an Agrison Diesel Generator.

Product_Catalog_Icon

 

25 KVA Diesel Generators
ELECTRICAL
FREQUENCY
VOLTAGE
PRIME
STANDBY
50HZ 3 PH
415V/230V
25KVA/20KW
27.5KVA/22KW
Rated Speed
1500RMP-50HZ
Circuit Breaker
4 Poles
Power Factor
0.8–3 Phase
ALTERNATOR
Model
TFW-20KW
Poles
4 poles
Winding Connections
star
Insulation
Class H
Enclosure
IP23
Exciter System
Self-regulating brushless
Voltage Regulator
AVR
Steady State Voltage Regulation
+/- 1.0%
Bearing
Single bearing sealed
Coupling
Flexible disc
Cooling
direct drive centrifugal blower fan
ENGINE
495ZD 50HZ
Output Rating KW 36
Manufacturer and model EuroTec
Fuel Diesel
Injection in-line
Aspiration turbo charger
Cylinders 4
Bore and Stroke MM 95*115
Displacement L 3.26
Cooling Water cooling
Engine Oil Specification SAE 3/11.5
Compression Ratio 17:1
Engine Oil Capacity L 13
Governor Mechanical
Air Filter Dry
Fuel Consumption
100% Load Prime G/KW.H ≤251.6
75% Load Prime G/KW.H ≤187.5
50% Load Prime G/KW.H ≤125.8
100% Load Standby G/KW.H ≤276.7
EXHAUST SYSTEM
Maximum Temperature 100% Standby
400
Exhaust Flange Size(Internal Diameter) MM 450
STARTING SYSTEM
Starter Motor KW
Battery Capacity AH 80
Auxiliary Voltage V 12
FUEL SYSTEM
Fuel Tank Capacity H 8 HOURS
WEIGHT AND DIMENSIONS – OPEN
Length mm 1700
Width mm 700
Height mm 1000
Wet Weight(Standard Build) kg 760
Dry Weight(Standard Build) kg 720
WEIGHT AND DIMENSIONS – CANOPY
Length mm 2000
Width mm 900
Height mm 1200
Wet Weight(Standard Build) kg 920
Dry Weight(Standard Build) kg 890
Sound pressure(LpA) – 7m Db 70
Alarms and shutdown functions
High Coolant Temperature S
Low Oil Pressure S
Unexpected Shutdown A
Battery Charge Alternator Failure A
Over Speed S
Failure to Start A
Emergency Stop A
Alternator-high Frequency S
S-Shutdown A – Alarm
Structure and Spec’s are subject to change without notice.